1-2-3.
INITIALIZATION OF E, F PAGE DATA
1. Initializing the E, F Page Data
Note1: If "Initializing the E, F Page Data" is performed, all data of the E
page and F page will be initialized. (It is impossible to initialize a
single page.)
Note2: If the E, F page data has been initialized, following adjustments
need to be performed again.

1) Modification of E, F page data

2) Camera system adjustments
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
E
Adjustment Address
00 to FF
Switch setting:
MODE .................................................................... CAMERA
Initializing Method:
Order Page Address Data
1
0
01
01
2
6
01
3
6
03
01
4
6
02
5
2. Modification of E, F Page Data
If the E, F page data has been initialized, change the data of the
"Fixed data-2" address shown in the following table by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3) When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F Page data
1) Select page: 0, address: 01, and set data: 00.
2) Turn off the power and turn on again.
Procedure
Set the data.
Set the following data, and press
PAUSE button.
2D: DSR-250 (NTSC)
2F : DSR-250P (PAL)
Set the data, and press PAUSE
button.
Check that the data changes to
"01".
Perform "Modification of E, F
Page Data".
3. F Page Table
Note1: Fixed data-1: Initialized data. (Refer to "1. Initializing the E, F
Page Data".)
Fixed data-2: Modified data. (Refer to "2. Modification of E, F
Page Data".)
Initial value
Address
NTSC PAL
00 to 0F
10 to 1B
1C
80
80
1D
1E
60
60
1F
40
60
20
00
00
21
15
15
22
00
00
23
2E
2E
24
AE
AE
25
2B
2B
26
44
44
27
43
43
28
B2
B2
29
16
16
2A
00
00
2B
00
00
2C
8B
8B
2D to 33
34
88
90
35
6C
8F
36
D6
D6
37
E6
E6
38
46
46
39
45
00
3A
3F
19
3B
3F
00
3C
16
27
3D
A8
A8
3E
38
38
3F
76
76
40
41
50
50
42
50
50
43
44
EB
EB
45
D5
D5
46
20
20
47
20
20
48 to 49
4A
00
00
4B
00
00
4C to 5C
5D
80
80
5E to 62
63
64
65 to 6F
70
89
89
71 to FF
5-14
Remark
Fixed data-1
27MHz origin osc. adj.
Fixed data-1
HALL adj.
AWB standard data input
Flange back adj.
MAX GAIN adj.
Fixed data-1
Auto white balance adj.
Flange back adj.
LV standard data input
Fixed data-1
Steady shot adj.
Fixed data-1
Color reproduction adj.
(ND filter OFF)
Fixed data-1
WB ND filter 1 compensation
Fixed data-1
Zoom key center adj.
Fixed data-1
Fixed data-2
Fixed data-1
HALL adj.
Fixed data-1
Table. 5-1-7.

Hide quick links: