Sharp AR-C360P Service Manual page 147

Hide thumbs Also See for AR-C360P:
Table of Contents

Advertisement

4 The screen in light on the overall. Or there is overall color drift in the printed image.
(Figure 7-2 A )
• Is there enough toner? (Is [Toner Short] displayed?)
YES
• NO
Is standard paper used?
NO
• YES
Is the LED head lens dirty?
YES
• NO
Is the entire LED head Assy properly connected to the relay PCB (S2H PWB)
and Engine PCB (S2V PWB)?
NO
• YES
Is the LED head pressing spring properly set?
NO
• YES
Are the protrusions on both sides of the LED head properly in contact with each
FG plate spring?
NO
• YES
Replace the LED head.
Has the problem been corrected?
YES
• NO
Replace the engine PCB (S2V PWB).
Has the problem been corrected?
YES
• NO
Replace the head shield cable.
Has the problem been corrected?
YES
• NO
Check the cable connection, then replace the low voltage power unit.
Has the problem been corrected?
YES
• NO
Is +24V output to the HVOLT connector pin 16 of the engine PCB (S2V PWB)?
NO
• YES
Check the cable connection, then replace the high voltage power unit or belt
cassette Assy.
Has operation been restored?
YES
• NO
Is the I/D unit terminal properly connected to the contact Assy? (Refer to Figure 7-3)
NO
• YES
Replace Image Drum Unit.
1. When replacing the Engine PCB (S2V PWB), remove the EEPROM from the old PCB,
Note
then mount that EEPROM on the new PCB.
2. If the EEPROM is not going to be replaced, refer to Section 5.2.2.
Rev. 1
Replenish toner.
Use standard paper.
Clean the LED head lens.
Check the cable connect (between each LED head and engine PCB),
then properly connect the cable between the LED head and engine PCB.
Properly set the pressing spring.
Correct the bend in the FG plate spring.
END
END
END
END
Replace the engine PCB.
END
Properly connect the I/D unit terminal to the contact Assy.
147 /