Superior WRT6036RS Installation And Operation Instructions Manual page 13

Indoor wood burning fireplace
Table of Contents

Advertisement

Terminations/Spark Arrestor
The fireplace system must be terminated with the listed round top or
chase terminations. In any case, refer to the installation instructions
supplied with the termination.
CAUTION: Do not seal openings on the rooftop
flashing. Follow the installation instructions provided
with the termination being used.
Stainless
Inner Flue
Pipe
Secure
Termination
to Outer
Pipe with 3
Screws
Overlap
Shingles (Top
and Sides of
Flashing Base)
Figure 18 - Termination
CHASE INSTALLATIONS
Instructions for chase installations are included with the chase style
termination chosen. In a multiple chase installation, be sure to provide
adequate distance between terminations to prevent smoke spillage
from one termination to another. We suggest that terminations be
separated at least 24", center to center and stacked at a vertical height
difference of 18" (see Figure 19).
Note: If a decorative shroud is to be installed, contact the manufacturer
for specifications.
24" Min.
24" Min.
Figure 19 - Multiple Chase Installation
126595-01C
VENTING INSTALLATION Continued
10 FOOT RULE
All flue gas outlet chimney terminations must extend a minimum of
3 feet in height above the highest point where it passes through the
roof and must be at least 2 feet above the highest point of the roof
that is within a horizontal distance of 10 feet (see Figure 20).
RLT-12D
Level of
Flue Gas
Outlet
Waterproof
Caulking
Storm
Collar
Flashing
FINISHING FIREPLACE
Combustible materials, such as wallboard, gypsum board, sheet rock,
drywall, plywood, etc. may make direct contact with sides and top
around the fireplace face. It is important that combustible materials
do not overlap the face itself. Brick, glass, tile or other noncombustible
Underlap
materials may overlap the front face provided they do not obstruct
Shingles
essential openings like louvered slots or any other opening. When
overlapping with a noncombustible facing material, use only noncom-
bustible mortar or adhesive.
18"
Min.
Typ.
Superiorfireplaces.US.com
Level of
10'
Flue Gas
Outlet
2' Min.
3' Min.
2' Min.
Figure 20 - 10 Foot Rule
10'
3' Min.
13