Download Print this page

Safety Warnings - Juniper BX7000 Getting Started Manual

Multi-acces
Hide thumbs Also See for BX7000:

Advertisement

Safety Warnings

WARNING:
a summary of safety warnings; for a complete list, including translations, see the
BX7000 Multi-Access Gateway Hardware Guide at
http://www.juniper.net/techpubs/hardware/.
WARNING:
(within-the-building) interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE, Issue 4) and require isolation from exposed outside plant (OSP)
cabling. To comply with NEBS requirements and to protect against lightning
surges and commercial power disturbances, the intrabuilding ports must not be
metallically connected to interfaces that connect to the OSP or its wiring. The
intrabuilding ports on the gateway are suitable for connection to intrabuilding or
unexposed wiring/cables only. The addition of primary protectors does not
provide sufficient protection to metallically connect these interfaces to OSP
wiring.
CAUTION:
strap to an ESD point and place the other end of the strap around your bare wrist.
Failure to use an ESD strap could result in damage to the gateway.
See installation instructions before connecting the routing node. This is
Certain ports on the gateway are designed for use as intrabuilding
Before removing or installing components of a gateway, attach an ESD
Only trained and qualified personnel should install or replace the gateway.
Perform only the procedures described in this guide or the BX7000 Multi-Access
Gateway Hardware Guide. Other services should be performed by authorized
service personnel only.
Before installing the gateway, read the guidelines for site preparation in the
BX7000 Multi-Access Gateway Hardware Guide to make sure that the site meets
power, environmental, and clearance requirements for the gateway.
Read the installation instructions before you connect the gateway to a power
source.
When mounting the gateway in a partially filled rack, load the rack from the
bottom to the top, with the heaviest components at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the gateway in the rack.
When removing or installing an electrical component, always place it
component-side up on a flat antistatic surface or in an electrostatic bag.
When installing the gateway, always make the ground connection first and
disconnect it last.
BX 7000 Multi-access Gateway Getting Started Guide
5
Safety Warnings

Advertisement

loading