Zoom And Af Checking; Iris Motor Check; Icr Check; Stabilizer Check - Sony SNC-RZ30N Service Manual

Hide thumbs Also See for SNC-RZ30N:
Table of Contents

Advertisement

2-4-5. Zoom and AF Checking

Performs the checking for zoom and focus motor
operations of the camera block automatically.
1. Click both Zoom and AF Check buttons of the Work
Flow column on the Pan/Tilt Adjuster screen. Then,
the following VISCA commands are issued
automatically.
81 01 04 57 00 FF
Normal AF Mode setting
81 01 04 07 25 FF
Tele speed: 5
After 2 seconds
81 01 04 07 00 FF
Stop
2. Confirm the following specification is satisfied.
Specification: . The color monitor images are zoomed
and then images in focus should be
displayed on the screen.
. "Complete Zoom, AF Check" should
be displayed on the screen of PC.
. Check mark should be placed in the
check box at the side of Zoom and AF
Check button.

2-4-6. Iris Motor Check

Performs the checking for iris motor operation of the
camera block automatically.
1. Click IRIS Check button of the Work Flow column on
the Pan/Tilt Adjuster screen. Then, the following
VISCA commands are issued automatically.
81 01 04 39 03 FF
Manual Mode setting
81 01 04 4B 00 00 00 00 FF
Close of IRIS
After 5 seconds
81 01 04 39 00 FF
Full Auto Mode setting
2. Confirm the following specification is satisfied.
Specification: . When click IRIS Check button, TV
monitor screen darkens immediately.
Approximately after 5 seconds, it
should returns to originally state.
. "Complete IRIS Check" should be
displayed on the screen of PC.
. Check mark should be placed in the
check box at the side of IRIS Check
button.
SNC-RZ30N/RZ30P (E)

2-4-7. ICR Check

Checks the ICR operation automatically.
1. Click ICR Check button of the Work Flow column on
the Pan/Tilt Adjuster screen. Then, the following
VISCA commands are issued automatically.
81 01 04 51 03 FF
Manual Mode setting
81 01 04 01 02 FF
ICR ON
After 5 seconds
81 01 04 01 03 FF
ICR OFF
2. Confirm the following specification is satisfied.
Specification: . When IRIS Check button is clicked,
TV monitor screen becomes darkens
mode (black and white images)
immediately. Approximately after 5
seconds, it should return to original
state (color images).
. "Complete ICR Check" should be
displayed on the screen of PC.
. Check mark should be located in the
check box at the side of ICR Check
button.

2-4-8. Stabilizer Check

Visually check if the stabilizer function operates normally.
1. Click Stabilizer Check button of the Work Flow
column on the Pan/Tilt Adjuster screen.
2. Click ON button. Then, the following VISCA
commands are issued automatically.
81 01 04 34 02 FF
Stabilizer function ON
3. Move the SNC-RZ30N/RZ30P to sideways quickly,
then confirm the following specification is satisfied.
Specification: Confirm the shaking on the TV monitor
screen has been stopped slowly
(Stabilizer ON).
4. Click OFF button. Then, the following VISCA
commands are issued automatically.
81 01 04 34 03 FF
Stabilizer function OFF
5. Move the SNC-RZ30N/RZ30P to sideways quickly,
then confirm the following specification is satisfied.
Specification: Confirm the shaking on the TV monitor
screen has been stopped immediately
(Stabilizer OFF).
6. Click END button.