Control unit
(cont.)
1 4
8

Vitotrol 300A

Part no. Z012 688
KM BUS subscriber.
■ Indicators:
– Room temperature
– Outdoor temperature
– Operating program
– Operating condition
– Heat-up condition of the heating water buffer cylinder, ash box full,
recharge fuel and heat-up (depending on boiler type).
■ Settings:
– Set room temperature for standard mode (normal room tempera-
ture) and reduced mode (reduced room temperature)
– Set DHW temperature
– Operating program, switching times for heating circuits, plus fur-
ther settings via plain text menu on the display
■ Party and economy mode can be enabled via the menu
■ Integrated room temperature sensor for room temperature hook-up
Installation site:
■ Weather-compensated mode:
Installation anywhere in the building.
■ Room temperature hook-up:
The integral room temperature sensor captures the actual room
temperature and effects any necessary correction of the flow tem-
perature.
The captured room temperature depends on the installation site:
– Main living room on an internal wall opposite radiators.
– Not on shelves or in recesses.
– Never in the immediate vicinity of doors or close to heat sources
(e.g. direct sunlight, fireplace, TV set, etc.).
Connection:
■ 2-core lead, length max. 50 m (even if connecting several remote
control units).
■ Never route this cable immediately next to 230/400 V cables.
■ LV plug included in standard delivery.

Vitotrol 350

CAN BUS subscriber
Control unit extension with touchscreen
The Vitotrol control unit extension is used for:
■ Remote control of the boiler with all relevant setting options
■ Display of all information pertinent to the boiler
■ Charge indicator for the heating water buffer cylinder
VITOLIGNO 200-S
Specification
Power supply via KM BUS
Power consumption
Safety category
IP rating
Permissible ambient temperature
– Operation
– Storage and transport
Setting range of the set room tempera-
ture for standard mode
1 5
5
Specification
Power supply via KM BUS
Power consumption
Safety category
IP rating
Permissible ambient temperature
– During operation
– During storage and transport
Setting range for set room temperature
■ Expansion of the system to include up to 20 additional control unit
extensions by CAN BUS (controller modules, data cable and con-
trollers required)
Possible extensions include:
– Control of a heating circuit with 1 temperature sensor
– Control of DHW heating with 2 temperature sensors
– Control of a long-distance heat line with 1 temperature sensor
(sub-distributor)
■ Setting of parameters and control of all extensions connected via
controller modules
0.2 W
III
IP 30 to EN 60529; ensure
through design/installation
0 to +40 °C
−20 to +65 °C
3 to 37 °C
0.5 W
III
IP 30 to EN 60529
Ensure through design/in-
stallation
0 to +40 °C
−20 to +65 °C
3 to 37 °C
VIESMANN
11
3