TANK FILL
Check the sight gauge and add more AW ISO VG
100 hydraulic fluid(Refer to list of recommended flu-
ids) to bring the level up between 1/2 to 3/4 on the
gauge. See Figure MntP-0017.
BLADES
Check the Blades for cracks and wear and Blade Bolts for tightness, daily. Blades should be replaced when
they are worn excessively, bent, deformed, or out of balance.
Blades should always be replaced in pairs.
imbalance and damage to the machine and personnel. When replacing blades, take care to
replace the blade bolts, nuts, and washers.
MACHETE 01/05
© 2005 Alamo Group Inc.
MAINTENANCE
Blades of different weights can cause serious
Maintenance Section 4-4