7-2. Operation Data

<Cooling>
Tempeature
condition(°C)
Indoor
Outdoor
27/19
35/-
<Heating>
Tempeature
condition(°C)
Indoor
Outdoor
20/-
7/6
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchaner path U bent.
(Thermistor themometer)
2. Connecting piping condition 5 m
Standard
Heat exchanger
pressure
pipe temp.
P (MPa)
T1 (°C)
0.9 to 1.1
9 to 11
Standard
Heat exchanger
pressure
pipe temp.
P (MPa)
T1 (°C)
2.4 to 2.6
43 to 45
– 20 –
FILE NO. SVM-12029
Indoor
fan mode
T2 (°C)
47 to 49
High
Indoor
fan mode
T2 (°C)
0 to 3
High
Outdoor
Compressor
fan mode
revolution
(rps)
High
54
Outdoor
Compressor
fan mode
revolution
(rps)
High
68