Lincoln Electric VANTAGE IM883-A Operator's Manual page 36

Lincoln electric welding system user manual
Table of Contents

Advertisement

E-5
PROBLEMS
(SYMPTOMS)
No welding power output.
Welder has output but no control.
Wire feeder does not work when
control cable is connected to 14 pin
connector.
No auxiliary power.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
1. Poor work lead connection to
work. Make sure work clamp is
tightly connected to clean base
metal.
2. "Weld Terminals" switch in wrong
position. Place switch in "Weld
Terminals On" position when
welding without control cable.
3. Faulty PC board or welder alterna-
tor.
1. Poor remote/control cable connec-
tion to 6-pin or 14-pin connector.
Check connections.
2. Faulty remote cable or faulty wire
feeder or wire feeder cable.
Replace if necessary.
3. Faulty control potentiometer or PC
board.
1. Wire Feeder Power circuit breaker
open. Check 42V and 120V
beakers and reset if tripped.
2. Faulty control cable. Repair or
replace cable.
3. Faulty wire feeder. Replace wire
feeder.
1. GFCI Receptacle may have
tripped. Follow "GFCI Receptacle
Testing and Resetting Procedure"
in the MAINTENANCE section of
this manual.
2. Faulty connections to auxiliary
receptacles. Check connections.
3. Faulty PC board or welder alterna-
tor.
VANTAGE
CAUSE
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
CAUTION
®
400
RECOMMENDED
COURSE OF ACTION
E-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vantage 400

Table of Contents