TROUBLESHOOTING AND REPAIR
F-17

TEST PROCEDURES

WIRE DRIVE MOTOR TEST

WARNING
Service and repair should only be performed by Lincoln Electric factory trained
personnel. Unauthorized repairs performed on this equipment may result in dan-
ger to the technician or machine operator and will invalidate your factory warran-
ty. For your safety and to avoid electrical shock, please observe all safety notes
and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to per-
form the test/repairs safely, contact the Lincoln Electric service department for
technical troubleshooting assistance before you proceed. Call 216-383-2531 or
1-800-833-9353(WELD).
------------------------------------------------------------------------------------------------
TEST DESCRIPTION
This test will help determine if the wire drive motor is receiving the correct voltage and
is capable of running properly. Either motor can be checked with this procedure.
MATERIALS NEEDED
5/16 in. nutdriver
Volt-Ohmmeter
DH-10