A-11
Magnum conduit to go between the reel cover and the
feedplate.
Gun Adapters (For DH Wire Drive Heads)
Adapts DH heads for desired gun connection
K489-7 for Fast-Mate (or European style) gun connec-
tions, including Dual Schedule Fast-Mate guns.
K1500-1 for standard Lincoln Innershield gun connec-
tion, or with Fast-Mate™ guns with K489-2 Fast-Mate
Adapter Kit. Also for Magnum 200/300/400 with
K466-1 Connection Kit or Magnum 550 with K613-1.
K1500-2 for Magnum 200/300/400 gun with K466-10
Connection Kit. (Also Tweco 4).
K1500-3 for Magnum 550 gun with K613-7
Connection Kit. (Also Tweco 5).
Install to either Head of the DH drive per instructions
shipped with the Gun Adapter.
Dual Procedure Switch Options
K683-1 Dual Procedure Switch (One per gun) -
Requires K686-2 Adapter for DH-10. Kit includes gun
switch, and mountings for Lincoln Innershield and
Magnum guns, with 15 ft (4.5 m) control cable and
3-pin plug. K686-2 Adapter permits 3-pin plug and
5-pin gun trigger plug to be connected to DH-10 5-pin
Trigger/Dual Procedure receptacle.
Connect the 5-pin plug of the K686-2 Adapter to the
DH-10 Wire Feeder Trigger/Dual Procedure 5-socket
receptacle.
The 3-pin plug of the K683-1 Dual Procedure switch
connects to the 3-socket receptacle of the Adapter,
and the 5-pin plug of the welding gun connects to the
5-socket receptacle of the Adapter.
K683-3 Dual Procedure Switch (One per gun) Kit
includes gun switch, and mountings for Lincoln
Innershield and Magnum guns, with 15 ft (4.5 m) con-
trol cable and 5-pin plug with two leads to connect to
gun trigger.
Connect the 5-pin plug of the K683-3 Dual procedure
Switch to the DH-10 Wire Feeder Trigger/Dual
Procedure 5-socket receptacle.
The two lead plug cord extending out of the 5-pin plug
of the Dual Procedure switch is to be connected to the
two trigger leads of the welding gun per the instruc-
tions shipped with the kit.
INSTALLATION
K590-4 Water Connection Kit (For DH Drive Only).
Install per the instructions shipped with the kit. One
used per gun.
K682-2 Water Connection Kit (K679 Single Head
Drive Only). Install to either side of wire feed unit
mounting bracket per instructions shipped with the kit.
K659-1 Gas Guard Regulator (One used per gun).
Adjustable flow regulator with removable adjustor key
for CO2 and Argon blend gases. Mounts onto feeder
inlet, and reduces gas waste and arc start "blow" by
reducing surge caused by excess pressure in supply
hose.
Install the 5/8-18 male outlet of the regulator to one, or
both of the 5/8-18 female gas inlets on the back panel
of the wire drive. Secure fitting with flow adjuster key
at top. Attach gas supply to 5/8-18 female inlet of reg-
ulator per GMAW Shielding Gas in this section.
K1449-1 Dual Procedure Remote Control. Provides
remote rotating knob encoder control of Wire Feed
Speed and Voltage, along with a dual procedure
selector switch, when the remote control is connected
and REMOTE is selected by the DH-10 Procedure
key. The DH-10 A or B procedure light will also be on
to indicate which procedure is selected by the remote
control.
The 4-pin plug of the remote control connects to the
mating receptacle on the bottom of the DH-10 Control
box. Only one remote is used with a DH-10 control.
The K1450-"L" Extension cable is used to extend the
16 ft (5 m) cable attached to the remote control.
Lengths "L" are available to match the Length of the
control to boom mount wire drive cable being used.
K1558-1 Remote Switch Interface Module, can be
used with the DH-10, using a G3041-2 (or higher)
Control Board.
The module provides for user interface connection of
an external switch (flow switch, etc) which must be
closed to enable the feeder welding operation. Also,
the module provides for interface connection of exter-
nal equipment (fume extractor, etc.) To the module's
isolated relay contacts which actuate when the feeder
welding gas solenoid is activated (representing weld-
ing operation in process).
When used with the DH-10, the module provides
these input and output switch function connections
independently for each head operation.
This module is necessary when using the K1536-1
waterflow sense kit with the DH-10.
DH-10
A-11