A-3

SELECT SUITABLE LOCATION

Locate the welder in a dry location where there is free
circulation of clean air into the louvers in the back and
out the front of the unit. A location that minimizes the
amount of smoke and dirt drawn into the rear louvers
reduces the chance of dirt accumulation that can block
air passages and cause overheating.
STACKING
SP-135 PLUS' cannot be stacked.

TILTING

Each machine must be placed on a secure, level sur-
face, either directly or on a recommended undercar-
riage. The machine may topple over if this procedure
is not followed.

OUTPUT CONNECTIONS

Refer to Figure A.2.
1. Work Cable Access Hole.
2. Gun Cable and Control Lead Access Hole.
3. Connector Block.
4. Gun Trigger Lead Connectors.
5. Positive (+) and negative (–) output terminals.
6. Wire Feed Gearbox and Gun Connector Block
7. Cable Clamp
8. Thumbscrew - Secures gun and cable assembly
9. Optional Spot/Stitch Timer Kit see Accessories.
SP-135 Plus
INSTALLATION
FIGURE A.2
5
WELDING AMP RANGE
WELDING AMP RANGE
25-125
25-125
8
1
2
Work Clamp Installation
Attach the work clamp per the following:
1. Unplug the machine or turn the power switch to the
"OFF" position.
2. Insert the work cable terminal lug with the larger
hole through the strain relief hole in the work clamp
as shown in Figure A-3.
3. Fasten securely with the bolt and nut provided.
Work Cable
Work Cable Installation
Refer to Figure A.2.
1. Open the wire feed section door on the right side of
the SP-135 PLUS.
2. Pass the end of the work cable that has the termi-
nal lug with the smaller hole through the Work
Cable Access Hole (1) in the case front.
4 4
+
-
6
3
7
SP-135 PLUS
FIGURE A.3
Strain Relief Hole
Nut & Bolt
Work Clamp
9
A-3