Installation; Technical Specifications - Lincoln Electric POWER WAVE F355I Operator's Manual

Lincoln electric welding system user manual
Hide thumbs Also See for POWER WAVE F355I:
Table of Contents

Advertisement

A-1

TECHNICAL SPECIFICATIONS -

Product Ordering
Input AC
Name Information Voltage
POWER
K2260-1
380-415
WAVE
K2260-2
F355i
60/50 Hz
3 Phase
* Overall Length without Mounting Brackets, 21.06" (535mm)
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Voltage
380
400
415
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Select The output cable size based upon the following chart.*
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE
CURRENT
100%
60%
*
Lincoln Electric recommends using a minimum of 2/0 welding cable for pulse welding.

INSTALLATION

POWER WAVE F355i
INPUT AC VOLTAGE & DC OUTPUT
Rated DC Output
Amps/Volts/Duty Cycle
350A / 34V / 60%
300A / 32V /100%
POWER WAVE F355i INPUT CURRENT
Output
Phases
300Amps @
32Volts(100%)
3
23
3
22
3
22
LENGTH UP 200FT.(61m)
300
350
POWER WAVE F355i (CE)
Output
Weight
Range
with Cord
(continuous)
AMPS
110.0 lbs.
5-425
(50.0. kg.)
Recommended
350Amps @
Line Cord
34Volts(60%)
28
10mm
27
10mm
26
10mm
2/0
2/0
Dimensions
HxWxD
14.6" x 17.2" x 27.6"*
(371 x 437 x 701*)mm
* Includes Mounting
Brackets
Fuse size
40A
2
40A
2
40A
2
200-250 FT. (61-76m)
2/0
2/0
A-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power wave f355i ce