Auxiliary Power; Limitations; Recommended Processes - Lincoln Electric INVERTEC V350-PRO IM708 Operator's Manual

Lincoln electric welding system user manual
Table of Contents

Advertisement

B-5

AUXILIARY POWER

• 115VAC, 42VAC and 24VAC power is available
from the two 14-pin amphenols on the rear of the
unit. (K1728-2 Construction model of the Invertec
V350-PRO (CE) does not have the amphenols)
These supplies are intended to supply power for
auxiliary equipment like wire feeders and the TIG
Module.
• 115VAC supply is rated at 2 amps and is protected
by a 2.5 amp breaker located by the amphenol.
• 42 VAC supply is rated at 5.5 amps and is protected
by a 6 amp breaker located by the amphenol.
• 24 VAC supply is rated at 5.5 amps and is protected
by a 6 amp breaker located by the amphenol.

LIMITATIONS

• The V350-PRO (CE) is not recommended for
processes other than those listed.
• The V350-PRO (CE) can only be used with the rec-
ommended equipment and options.

RECOMMENDED PROCESSES

Properly equipped, the Invertec V350-PRO (CE)
supports GMAW, FCAW, SMAW, GTAW and CAC-
A processes for a variety of materials, including
mild steel, stainless steel, cored wires, and alu-
minum
OPERATION
V350-PRO (CE)
B-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec v350-pro ce

Table of Contents