Appendix A
6. The "Start", "Short", and "End" windows can
be adjusted at this time to optimize the
starting, shorting, and ending routines.
Our Experiment: We needed to adjust the
starting variables. With the feeder's run-in
WFS set at 65 in/min, we set the starting
variables to control the starting routine. With
the assistance of ArcScope, we found good
settings with these values: start volt 21.0,
start time 35 milliseconds, and start current
180 amps. The OCV strike peak time and
amps were acceptable as set.
7. Click on the
WorkPoint Editor window. Check only those
wire feed speed points that have been
developed (only 150 in/min. at this point). The
WorkPoint Editor can also be used to change
the wire feed speed value of a workpoint.
Workpoints can have the same value but must
be in numerical order.
Select the
shape parameters for all workpoints equal to
the wave shape parameters of the 150 in/min.
workpoint. Close the WorkPoint Editor window.
PULSE WAVE SHAPING PRINCIPLES
button to display the
button to set the wave
WAVE DESIGNER
Start Control - Pulse
Start Control
For Wire Feed Speed
150
Stage 1 : Wire Run In
48.0
Open Circuit Volt
Stage 2 : Striking Pulse
2.0
Strike Peak Time
550
Strike Peak Amps
Stage 3 : Arc Length Control
21.0
Start Volt
88
Start Time
Stage 4 : Current Control
172
Start Amps
WorkPoint Editor
WorkPoint Editor
50
700
0
8
80
850
1
9
110
1000
2
10
150
1200
11
3
205
4
300
5
400
6
600
7
inch / min
meter / min
Go Figure
A-19