A-2
A.2 GMAW PULSE OVERVIEW
Figure A-1 illustrates the variables of the GMAW-P welding process. Each of these variables can
be programmed into a weld table using the Wave Designer software. Figure A-2 shows how the
pulse waveform and the primary variables shape, detach and propel a weld droplet across the
arc.
For more details on each of these variables, refer to Primary Pulse Waveform Components
and Secondary Pulse Waveform Components in paragraphs A.5 and A.6 of this appendix.
PULSE WAVE SHAPING PRINCIPLES
FIGURE A-1. PULSE WAVEFORM PARAMETERS.
PEAK TIME
% OVERSHOOT
File
Tools
Print
Help
Pulse Waveform Editor
50
Edit
Wire Feed Speed
600
Ramp Up Rate
Ramp Overshoot %
-20
Peak Amps
250
Peak Time ms
1.2
Tailout Time
3.0
.100
Tailout Speed
Stepoff Amps
40
21
Backgrd Amps
33.4
Backgrd Time
Frequency
26.4
Start
Adapt
Short
End
About
Status
AC.sco loaded
WAVE DESIGNER
TAILOUT
TIME
TAILOUT
SPEED
PEAK
AMPS
1/FREQUENCY
Wave Designer Pro Off Line - pulse.swf
700
600
500
400
300
200
100
0
0
3
6
9
12
15
Off Line
Appendix A
STEP-OFF
AMPS
BACKGROUND AMPS
BACKGROUND
TIME
27850026
18
21
24
27
30
Stand by
Adaptive
27850027

Advertisement

loading

This manual is also suitable for:

Wave designer