Section 3
5. Optional Windows The optional window buttons open additional windows used during
wave shaping. Optional windows in the pulse Waveform Editor include Start, Adapt, Short,
End, and About. Details about the use of most optional windows is covered in the applicable
appendix (i.e. Appendix A for Pulse Wave Shaping). We use the About window shown in
Figure 3-3 to record descriptive weld application data for custom wave shape files. This
information is stored with the program in the computer and in the Power Wave.
6. Wave Designer Status Bar This status bar provides a scrolled listing of recent program
events, error conditions, etc. Use the arrow keys
bar includes three system status indicators: on line/off line, standby/welding, and
adaptive/non-adapt. The adaptive indicator is also a button that toggles between the
adaptive and non-adaptive mode.
7. Volts/Amps Display The Volts/Amps display, Figure 3-4, provides real time, oscilloscope
type displays of the voltage and amperage outputs from the connected power source.
Smaller display monitors (640 x 480 pixels or less) will not show the volts/amps display.
SOFTWARE OPERATION
FIGURE 3-3. THE "ABOUT" EDIT WINDOW.
About the Procedure
About the Procedure
Process Type
Wire Type
Process Name
Procedure
FIGURE 3-4. TYPICAL VOLTS/AMPS DISPLAY.
On Line
WAVE DESIGNER
GMAW
Other
Wire Size
6.3mm
Steel Pulse A
.035 Steel
super GAS
Gas
27850007
to scroll through the listings. The status
∂ ƒ
Welding
Adaptive
3-3
27850008

Advertisement

loading

This manual is also suitable for:

Wave designer