Sharp FACSIMILE FO-4500 Service Manual page 51

Hide thumbs Also See for FACSIMILE FO-4500:
Table of Contents

Advertisement

SW71 No. 5 ~ No. 8 All white page detection
(When transmission scanning)
Ratio of black and white during duplex scan.
SW72 No. 1 ~ No. 4 Black line detection (When copy scanning)
Number of continuous judgements of black lines during duplex scan.
SW72 No. 5 ~ No. 8 White page detect (When copy scanning)
Ratio of black and white during duplex scan.
SW73 No. 1 Drum life control
Used to set ON/OFF of the "DRUM LIFE OVER" indicator.
SW73 No. 2 ~ No. 7 Reserved
Set to "0".
SW73 No. 8 Reserved
Set to "1".
SW74 No. 1 ~ No. 8 Reserved
Set to "0".
SW75 No. 1 ~ No. 8 Reserved
Set to "0".
SW76 No. 1 ~ No. 8 Reserved
Set to "0".
SW77 No. 1 ~ No. 8 Reserved
Set to "0".
SW78 No. 1 ~ No. 8 Reserved
Set to "0".
SW79 No. 1 ~ No. 8 Reserved
Set to "0".
SW80 No. 1 ~ No. 8 Reserved
Set to "0".
SW81 No. 1 ~ No. 8 Reserved
Set to "0".
SW82 No. 1 ~ No. 8 Reserved
Set to "0".
SW83 No. 1 ~ No. 8 Reserved
Set to "0".
SW84 No. 1 ~ No. 8 Reserved
Set to "0".
SW85 No. 1 ~ No. 8 Reserved
Set to "0".
SW86 ~ SW94 No. 1 ~ No. 8 Reserved
Set to "0".
SW95 No. 1, No. 2 DTMF detection time
Used to set detect time of DTMF (Dual Tone Multi Frequency) used in
remote reception (5
).
The longer the detect time is, the less the error detection is caused by
noises.
SW95 No. 3 Protection of remote reception (5
Used to set the function of remote reception (5
the remote reception function is disabled.
SW95 No. 4 Reserved
Set to "0".
SW95 No. 5 ~ No. 8 Remote operation code figures by external
TEL (0 ~ 9)
Remote operation codes can be changes from 0 through 9. If set to
greater than 9, it defaults to 9. The "5
Ex-7
(Default: 5
)
) detect
). When set to "1",
" is not changed.
2 – 35
SW96 No. 1 Reserved
Set to "0".
SW96 No. 2 Recall control of same dial
If a call to the same person is continuously made, the recall operation
of second call is limited.
SW96 No. 3 Summer time
0: Summer time function enabled
1: Summer time function disabled
SW96 No. 4 U.K./Ireland mode
UK/IR selection
Default: 0
SW96 No. 5 Mercury function
0: No
1: Yes
Default: 0
SW96 No. 6, No. 7 PBX Recall selection
PBX function
RECALL selection machine
Default: 10 (Earth)
SW96 No. 8 Lower frequency for CI detection
Ring signal for auto reception is set.
When this switch is set to "1", PTT standards are set.
SW97 No. 1 ~ No. 3 Reserved
Set to "0".
SW97 No. 4, No. 5 Reserved
Set to "1".
SW97 No. 6 Reserved
Set to "0".
SW97 No. 7 Reserved
Set to "1".
SW97 No. 8 Reserved
Set to "0".
SW98 No. 1 Waiting time after dialing
This is the time waiting for the opponent's signals after dialing.
For the Switzerland version, the time is fixed to 90 sec regardless of
this switch setting.
SW98 No. 2 ~ No. 8 Reserved
Set to "0".
SW99 No. 1 ~ No. 8 Reserved
Set to "0".
FO-4500H

Advertisement

Table of Contents
loading

Table of Contents