OPERATION

FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance is equipped with an igni-
tion device which automatically lights
the pilot. Do not try to light by hand.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don't try to repair it, call a qualified
service technician. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be pres-
ent. Open damper or window to
vent smell. This will only last a
few hours.
1. STOP! Read the safety information,
above.
2. Open lower louver panel.
3. Turn off all electric power to fireplace.
28
4. Push in gas control knob slightly and turn
clockwise
5. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow "B"
in the safety information in column 1. If
you don't smell gas, go to the next step.
6. The pilot is located by the main burner and
should not require accessing for lighting.
7. Turn gas control knob counterclockwise
8. Push in gas control knob all the way and
hold. Immediately light pilot by repeatedly
pressing piezo spark ignitor until a flame ap-
pears. Continue to hold for about 1 minute
after pilot is lit. Release gas control knob
and it will pop back. Pilot should remain lit.
If it goes out, repeat steps 4 through 7.
• If gas control knob does not pop up when
released, stop and immediately call our
service technician or gas supplier.
• If pilot will not stay lit after several tries,
turn gas control knob to OFF and call
your service technician or gas supplier.
9. Turn on all electric power to fireplace.
10. Turn gas control knob counterclockwise
11. This valve is equipped with a HI/LO fea-
ture. Set fireplace input as desired.
12. To leave pilot lit and shut off burners only,
turn control knob clockwise
PILOT position then set selector switch in
the OFF position.
13. Close lower louver panel.
Gas Control
Knob
Piezo
Ignitor
1. Open lower louver panel.
2. Set selector switch in the OFF position to
prevent draining battery.
3. Turn off all electrical power to the appli-
ance if service is to be performed.
4. Push in gas control knob slightly and turn
clockwise
5. Close lower louver panel.
6. Close equipment shutoff valve (see
Figure 33, page 22).
www.desatech.com
to OFF.
to PILOT.
to ON.
Variable Control Knob
Figure 52 - Control Valve
TO TURN OFF GAS
TO APPLIANCE
to OFF.
to the