OPERATION
Continued
Note: Do not leave the hand-held remote in the
AUTO mode close to the fireplace. The radiant
heat from the fireplace will turn off the fireplace.
Ideally, place the hand-held remote in the center
of the room facing towards the fireplace.
Note: Do not hold the hand-held remote for
a long time. Body temperature will affect its
operation in the AUTO mode.
Safety Features
When away from home for an extended period of
time or as a child safety feature to prevent acciden-
tal ignition of the fireplace, the receiver ON/OFF/
REMOTE switch should be in the OFF position.
Auto Shutoff Feature
1. If the average room temperature reaches
a range of 82° F (28° C) to 92° F (33° C),
the hand-held remote control will perform a
safety override and shut the fireplace off. This
feature is not available in the MANU mode.
2. The receiver continuously receives signals
from the hand-held remote to control the
room temperature. If the hand-held remote
is misplaced, obstructed or for any reason
cannot transmit to the receiver, the receiver
will shut off the fireplace. This will occur in 8
or more minutes depending upon location of
remote transmitter and strength of batteries.
Key Pad Lock Feature
This feature allows the user to lock/unlock the
keypad on the hand-held remote in the MANU
or AUTO mode to prevent inadvertent op-
eration (i.e. children operating the hand-held
remote control, etc.). The keypad is locked in
either on or off. Press the POWER and LOCK
buttons together to turn the unit on or off.
Digital Display Shows
Temperature and Settings
Locks
System to
Prevent
Accidental
ROOM
TEMP
Ignition
Turns
LOCK
Burners
On or Off
MANU
Increases or
Decreases
Room
Temperature
in AUTO
Mode
Figure 55 - Thermostat Hand-Held
Remote Control Unit HRC200
30
Turns
Hand-Held
AUTO
Remote On
SET
TEMP
or Off and
Allows You
TEMP
POWER
to Choose
the Manual
Setting
AUTO
ºC/ºF
Selects
AUTO
Mode
°C/°F Mode
Button
www.desatech.com
OPERATING OPTIONAL
GWMT1 WALL MOUNTED
THERMOSTAT
WARNING: Do not con-
nect the thermostat to a power
source. Electrical shock and/or
a fire hazard will occur.
Light the fireplace as instructed in Lighting
Instructions on page 28. Set wall thermostat
to desired temperature.
This thermostat has been electronically cali-
brated at the factory and requires no adjust-
ment or leveling.
Upon installation, the thermostat must be al-
lowed to stabilize at room temperature for a
minimum of 30 minutes for proper operation.
To turn the fireplace off, adjust thermostat to
the lowest setting and turn the gas control
knob back to PILOT. The pilot will remain lit.
IMPORTANT: To turn the pilot off, turn the
gas control knob on the heater to the OFF
position.
OPERATING OPTIONAL
BLOWER ACCESSORY
Locate the blower controls by opening the
lower louver panel on the fireplace. Blower
controls are located on the left side of the
switch bracket to the left just inside the louver
panel.
The BK manual blower and the BKT ther-
mostatically-controlled blower have an ON
setting and an OFF setting. The blower will
only run when the switch is in the ON posi-
tion. In the OFF position, the blower will not
operate.
Note for BKT Only: If you are using BKT
blower with optional thermostat (wall mounted
or remote control) for the fireplace, your fire-
place and blower will not turn on and off at the
same time. The fireplace may run for several
minutes before the blower turns on. After
the heater modulates to the pilot position,
the blower will continue to run. The blower
will shut off after the firebox temperature
decreases.
The blower helps distribute heated air from
the fireplace. Periodically check the louvers of
the firebox and remove any dust, dirt, or other
obstructions that will hinder the flow of air.
111986-01F