Desa (V)T32N series Owner's Operation And Installation Manual page 20

Direct-vent "tudor" models
Table of Contents

Advertisement

FIREPLACE
INSTALLATION
Continued
11. Peel off backing paper and stick supplied
wiring diagram decal on firebox bottom
approximately 12" in front of blower (see
Figure 27, page 19).
Blower Wiring Diagram
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring errors
can cause improper and dan-
gerous operation. Verify proper
operation after servicing.
Variable
Fan Switch
1
Off
110/115
V.A.C.
Black
White
Green
Figure 29 - Blower Wiring Diagram for
Thermostat-Controlled Models
INSTALLING GAS PIPING TO
FIREPLACE LOCATION
WARNING: A qualified
service person must connect
fireplace to gas supply. Follow
all local codes.
CAUTION: For propane/LP
units, never connect fireplace
directly to the propane/LP supply.
This heater requires an external
regulator (not supplied). Install
the external regulator between the
fireplace and propane/LP supply.
WARNING: For natural
gas, never connect heater to
private (non-utility) gas wells.
This gas is commonly known
as wellhead gas.
20
Fan Switch
(N.O.)
Black
2
On
Blue
Blower
Motor
www.desatech.com
Installation Items Needed
Before installing fireplace, make sure you have
the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with gas connec-
tor (if allowed by local codes)
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable alter-
native to test gauge connection. Purchase the
CSA design-certified equipment shutoff valve
from your retailer.
For propane/LP connection only, the installer
must supply an external regulator. The ex-
ternal regulator will reduce incoming gas
pressure. You must reduce incoming gas
pressure to between 11" and 14" of water. If
you do not reduce incoming gas pressure,
fireplace regulator damage could occur. Install
external regulator with the vent pointing down
as shown in Figure 30. Pointing the vent down
protects it from freezing rain or sleet.
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" inside diameter or greater to
allow proper gas volume to fire-
place. If pipe is too small, undue
loss of volume will occur.
External
Regulator
with Vent
Pointing
Down
Figure 30 - External Regulator with Vent
Pointing Down (Propane/LP Only)
Propane/LP
Supply Tank
111986-01F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents