2. Top Vent - Vertical Termination
No Elbow
Note: Use SLP Series
components only.
Note: If installing a vertical vent/termination off the top of the
appliance, the exhaust restrictor may be needed.
V
= 3 ft. Min. (914 mm)
1
V
= 50 ft. Max (15 m)
1
Figure 7.7
Exhaust restrictors are recommended for these verti-
cally terminated products which have excessive draft.
Exhaust restrictors will compensate for high draft, and
restore visual fl ame height. If the vent confi guration has
a total vertical of 15-50 feet, an exhaust restrictor may
be needed. The exhaust restrictor can be located in the
appliance manual bag.
V
1
Heatilator • GDST3831I • 2127-900 Rev. N • 6/15
Exhaust restrictor Instructions
1. Center the exhaust restrictor in the open end of the ex-
haust outlet and secure through the slots on the exhaust
restrictor with the 2-1/4 in. self tapping screws provided
in the appliance manual bag.
Figure 7.8
EXHAUST
RESTRICTOR
29