Fault Codes - Lincoln Electric POWER MIG IM736-D Operator's Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

E-6
Code
Description
39
Glitch on the primary over
current fault interrupt; possibly
caused by noise or a signal level
(misc. hardware fault #1)
44
Main CPU problem. The DSP
has detected a problem with the CPU.
47
Glitch on the CAP/heart beat
interrupt; possibly caused by
noise or a signal level right at
the trip threshold.
(misc. hardware fault #2)
81
Motor overload-average motor
current exceeded 8.00 amps for
more than 0.50 seconds
82
Motor overcurrent-average motor
current exceeded 3.50 amps for
more than 10.0 seconds
Displays
Scrolling dash
"Err" "####"
"----" "----"
"####" "####"(on steady) Machine output is on. Left display is current, right display is voltage.
"####" "####" (blinking)
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
Check the machine ground.
If problem persists contact an
authorized Lincoln Field Service
Shop.
Check the machine ground.
If problem persists contact an
authorized Shop.
Verify motor armature is not
binding. Verify Wire Spool
is not binding.
Verify wire can move freely in
cable. Verify Spool Brake is not
set to tight.
Description
Appears at power up while the machine is going through its self configu-
ration
Fault code display. The first fault to occur will be displayed for three
seconds. The display will cycle through fault codes for all faults that
persist after the initial three-second period are displayed for 1 sec-
ond each.
Weld mode is changing
If actively welding, the displays are arc current and arc voltage. If
not actively welding, the display will show work point.
Weld just finished – the average arc voltage and current will be
blinked for 5 seconds following a weld. If the work point changes
during this 5 second period, the display will revert to the above
mode.
POWER MIG 300

Fault Codes

Misadjustment(s)
CAUTION
E-6
Corrective Action
Self-clearing as
condition ceases.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power mig 300

Table of Contents