For Power Sources Other Than Lincoln Electric - Lincoln Electric LN-8 SVM132-A Service Manual

Semiautomatic wire feeder
Table of Contents

Advertisement

A-14
FIGURE A.10 – FOR POWER SOURCES OTHER THAN LINCOLN ELECTRIC
POWER SOURCE
INTERNALLY POWERED CONTACTOR
OUTPUT CONTACTOR COIL
FOR POWER TO
OPERATE CONTACTOR
MAX. RATING OR LN-8
#2 TO #4 CIRCUIT IS
5 AMP 115 VAC OR
5 AMP 28 VDC
1/2 AMP 115 VDC
TO 115 VAC 350
VOLT-AMP CAPACITY
TAPE UP
EACH LEAD
TO LN-8 CIRCUIT
CONTROL
31
32
2
4
LN-8 WIRE FEEDER
REFER TO THE POWER SOURCE WIRING DIAGRAM TO FIND THE TYPE OF CONTACTOR CIRCUIT.
INSTALLATION
WARNING
TURN OFF INPUT POWER
TO THE WELDING POWER
SOURCE USING THE
DISCONNECT SWITCH
BEFORE WORKING
ELECTRIC
ON THIS EQUIPMENT.
SHOCK
CAN KILL
ELECTRODE
WORK
GND
21
4
2
31
32
75
76
TO
77
WORK
INPUT
CABLE
ELECTRODE CABLE
POWER SOURCE
EXTERNALLY POWERED CONTACTOR
OUTPUT CONTACTOR COIL
(115 VAC)
MAX. RATING OF LN-8
#2 TO #4 CIRCUIT IS
5 AMP 115 VAC
5 AMP 28 VDC
1/2 AMP 115 VDC
TO 115 VAC 350 VOLT-AMP
FOR LN-8 PLUS
CONTACTOR
REQUIREMENTS
TAPE UP
EACH LEAD
TO LN-8 CIRCUIT
CONTROL
31
32
2
4
LN-8 WIRE FEEDER
CLEVELAND, OHIO U.S.A.
LN-8
ELECTRODE
WORK
GND
21
4
2
31
32
75
76
TO
77
WORK
INPUT
CABLE
ELECTRODE CABLE
A-14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ln-8

Table of Contents