TECHNICAL SPECIFICATIONS – IDEALARC
Standard Voltage/Frequency
208/230/60 Hz
230/460/575 Hz
Duty Cycle
35%
60%
100%
Welding Current Range
30-250 Amps
Input
Fuse or
Voltage/
Breaker Size
Frequency
(Super Lag)
208
60
230
60
460
30
575
25
Height
28.2 in
719 mm
OPERATING TEMPERATURE
-20° C TO 40°C
INSTALLATION
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
Maximum Open Circuit Voltage
RECOMMENDED INPUT CABLE AND FUSE SIZES
Input Ampere
Rating on
Nameplate
53
50
25
20
PHYSICAL DIMENSIONS
Width
18.8 in
480 mm
®
SP-255
Input Current (@ Max Rated Output)
53/49 Amps
50/25/20 Amps
Amps
250 Amps
200 Amps
145 Amps
OUTPUT
40 Volts
75C Copper Wire 75C Copper Wire
in Conduit
in Conduit
AWG (IEC)
AWG (IEC)
Sizes
For lengths
For lengths
up to 100 ft.
exceeding 100 ft.
2
8 (10 mm
)
6 (16 mm
2
10 (6 mm
)
8 (10 mm
2
14 (2.5 mm
)
12 (4 mm
2
14 (2.5 mm
)
12 (4 mm
Depth
40.1 in
1019 mm
STORAGE TEMPERATURE
Volts at Rated Amperes
26 Volts
28 Volts
26 Volts
Wire Speed Range
50-600 IMP (1.27-15.2 m/min)
Sizes
Ground Wire
2
)
#10 (6 mm
2
)
#10 (6 mm
2
)
#10 (6 mm
2
)
#10 (6 mm
Weight
222 Ibs
101 kg
±40°C
AUG 95
IDEALARC SP-255
A-1
2
)
2
)
2
)
2
)