Lincoln Electric COMMANDER SVM145-B Service Manual page 152

Lincoln electric welder user manual
Table of Contents

Advertisement

F-96
STATOR/ROTOR REMOVAL AND REPLACEMENT (continued)
LEADS #229
AND #242D
PREPARATION AND LEAD REMOVAL
PROCEDURE
1. Turn the engine off.
2. Perform the Case Cover Removal Pro-
cedure, including removing the output panel.
3. Perform
the
Rectifier
Bridge
Procedure.
4. Using the 3/8" wrench, remove leads #229
(white) and #242D from the fuel level sensor.
See Figure F.44.
reassembly.
TROUBLESHOOTING & REPAIR
FIGURE F.44 – FUEL TANK REMOVAL DETAILS
Power
Module/Output
Assembly
Removal
Label the leads for
COMMANDER 300
5. Turn the fuel off at the shutoff valve. Remove
and plug the fuel return line.
F.44.
6. Remove and plug the lower fuel line. Pull it
through the firewall. See Figure F.44.
7. Using the 9/16" socket wrench, remove the
four lock nuts, washers, and rubber washers
from from the fuel tank mounting U-bolts.
See Figure F.44.
8. Carefully remove the U-bolts and lift the fuel
tank from the machine.
F-96
PLUG
FUEL
LINES
U-BOLTS (2)
See Figure