Lincoln Electric COMMANDER SVM145-B Service Manual page 128

Lincoln electric welder user manual
Table of Contents

Advertisement

F-72
Right Chopper Board
+
Plug J13
TEST PROCEDURE
1. Turn the engine off.
2. Using
the
Case
Replacement Procedure and tilt the control panel
out.
WARNING
ELECTRIC SHOCK CAN KILL.
• Do not touch electrically live
parts such as output terminals
or internal wiring.
• Insulate yourself from the work
and ground.
• Always wear dry insulating
gloves.
3. Start the machine.
4. In the CC mode, load the machine on a load grid to
375 amps at 34 VDC.
TROUBLESHOOTING & REPAIR
PWM OUTPUT TEST (continued)
FIGURE F.34 – Plug J13 w/pins 4 & 5
Cover
Removal
and
FIGURE F.35 – Plug J1 pin 6
Plug J1
COMMANDER 300
Plug J13
Pin 4
5. Using an oscilloscope, measure the PWM wave-
form from J13 pin 5 (probe) to J13 pin 4 (gnd) at the
right chopper board. See Figure F.34.
6. Turn the weld terminals switch to the "Remotely
Controlled" position. The PWM waveform on the
scope should go to zero and the machine output
should go to zero.
7. Connect a remote control to the machine amphe-
nol. Turn the remote 2-4 switch to the "on" position.
The PWM waveform should reappear and the
machine output should be re-established.
8. Disconnect the remote control.
9. If the PWM waveform does not change, use a volt-
meter to check for 10.0 VDC from J1 pin 6 to frame
ground with the weld terminal switch in the remote-
ly controlled position. See Figure F.35.
10. Turn the weld terminals switch to the "always on"
position and the control dial to the max position.
Pin 6
F-72