F-58
CHECK DIODE MODULE
8. Using the analog ohmmeter, connect the
negative meter probe to the terminal on the
diode module. See Figure F.27. Connect the
positive meter probe to the heat sink. The
resistance should be very high (over 20,000
ohms).
9. Using the analog ohmmeter, connect the
positive meter probe to the terminal on the
diode module. See Figure F.27. Connect the
negative meter probe to the heat sink. The
resistance should be low (approximately
1000 ohms).
TROUBLESHOOTING & REPAIR
POWER MODULE TEST (continued)
FIGURE F.27 – DIODE MODULE TEST
DIODE MODULES
AND HEAT SINKS
COMMANDER 300
10. Reconnect all leads and sheet metal previ-
ously removed.
11. Torque the capacitor nuts to 50-60 inch-
pounds.