Mitsubishi Electric MXZ-2A40VA Service Manual page 97

Split-type, heat pump air conditioners outdoor unit
Hide thumbs Also See for MXZ-2A40VA:
Table of Contents

Advertisement

MXZ-4A80VA
15-8. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
Part numbers that are circled are not shown in the illustration.
No.
Parts No.
1
M21 TK0 501
PROPELLER
2
M21 TK0 301
OUTDOOR FAN MOTOR
T2W YH1 440
3
POWER BOARD
4
T2W YH1 451
ELECTRONIC CONTROL P.C. BOARD
5
M21 TK0 337
REACTOR
6
T2W YH1 424
NOISE FILTER P.C. BOARD
7
T2W YH1 376
TERMINAL BLOCK
8
T2W E64 376
TERMINAL BLOCK
9
T2W E70 307
GAS PIPE TEMPERATURE THERMISTOR
10
T2W TK0 398
R.V. COIL
M21 G0H 308
11
THERMISTOR SET
12
M21 90V 309
AMBIENT TEMPERATURE THERMISTOR
13
T2W YH1 381
FUSE
14
T2W YH1 382
FUSE
15
T2W E88 313
FUSE&VARISTOR SET
15-9. ACCESSORY
No.
Parts No.
16
T2W E59 704
DRAIN SOCKET ASSEMBLY
Parts Name
Parts Name
Q'ty/unit
Symbol
in Wiring
MXZ-4A80VA-
Diagram
MF
L
TB2~5
TB1
RT6A,B,C,D
21S4
RT61,62,68
RT65
F801
F911
F64,NR64
Q'ty/unit
Symbol
in Wiring
MXZ-4A80VA-
Diagram
97
Remarks
E1
1
1
PM8H60-
1
Including heat sink and RT64
1
1
220+ 400V
1
4
Indoor unit connecting
1
Power supply
1
1
DEFROST, DISCHARGE,
1
OUTDOOR HEAT EXCHANGER
1
1
3.15A 250V
1
1A 250V
1
2A 250V
Remarks
E1
DRAIN SOCKET O1
1
DRAIN CAP O2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents