D D Check Of Lev - Mitsubishi Electric MXZ-2A40VA Service Manual

Split-type, heat pump air conditioners outdoor unit
Hide thumbs Also See for MXZ-2A40VA:
Table of Contents

Advertisement

• When cooling, heat exchanger of non-operating indoor unit frosts.
• When heating, non-operating indoor unit get warm.

D D Check of LEV

LED display:
Turn on power supply to the outdoor unit after checking LEV coil is mounted to the
LEV body securely.
Is "click - click" sound heard?
Or, do you feel vibration of LEV coil with a hand?
No
Disconnect the connector
CN791: LEV A, CN792: LEV B, CN793: LEV C,
CN794: LEV D, CN795: LEV E.
Is there normal resistance to LEV coil?
No
Replace LEV coil.
LED1
LED2
Lighting
Lighting
Lighting
Once
Yes
Normal
Yes
Replace the inverter P.C. board or
the outdoor electronic control P.C. board.