OPERATING PROCEDURE
Photo 5
Compressor nuts

2. Removing the fan motor

(1)Remove the top panel, the service panel, and the cabinet.
(Photo 1)
(2)Disconnect the connector CN931 and CN932 on the outdoor
electronic control P.C. board.
(3)Remove the propeller.
(4)Remove the fan motor.
R.V. coil
4 way valve
LEV coil
Expansion valve
Suction pipe
welded part
Discharge
pipe welded part
Photo 3
Screws of
the back panel
Screws of
the back panel
Photo 4
Screws of
the electrical
parts
Photo 6
Screws of the outdoor fan motor
Propeller
Propeller nut