Technical Changes; Revision : A - Mitsubishi Electric MXZ-2A40VA Service Manual

Split-type, heat pump air conditioners outdoor unit
Hide thumbs Also See for MXZ-2A40VA:
Table of Contents

Advertisement

Revision : A

• MXZ-3A54/4A71VA-
E2
Quick clean kit has been removed.(Refer to 2)
• MXZ-2A40/52VA-
has been added.
E1
1

TECHNICAL CHANGES

MXZ-A26WV -
E1
1. Indication of capacity has been changed. (BTU kW)
2. Capacity specification has been changed. (Cooling capacity 7.1kW 5.4kW)
3. Dimensions of unit has been changed. (W900oH900oD320 W840oH710oD330)
4. Combinations of connectable indoor units have been changed.
5. Capacity class of connectable indoor units have been changed.
6. Communication system has been changed.
7. Power supply way has been changed(change to supply to outdoor unit).
8. Compressor has been changed. (TNB220FMCH SNB130FLDH1)
9. High-pressure switch has been removed.
10.Outdoor fan motor has been changed. (PM8H60-UA RC0J60-AA)
11.Evaporation temperature thermistor has been removed.
12.Ambient temperature thermistor has been added.
13.New dip switch has been added to the controller board for "Locking the operation "mode
and "Lowering the operating noise "mode.
14.A Quick Clean Kit has been added.
MXZ-A32WV -
E1
1. Indication of capacity has been changed. (BTU kW)
2. Capacity specification has been changed. (Cooling capacity 8.0kW 7.1kW)
3. Dimensions of unit has been changed. (W900oH900oD320 W840oH710oD330)
4. Combinations of connectable indoor units have been changed.
5. Capacity class of connectable indoor units have been changed.
6. Communication system has been changed.
7. Power supply way has been changed(change to supply to outdoor unit).
8. Compressor has been changed. (TNB220FMCH SNB130FLDH1)
9. High-pressure switch has been removed.
10. Outdoor fan motor has been changed. (PM8H60-U RC0J60-AA)
11. Evaporation temperature thermistor has been removed.
12. Ambient temperature thermistor has been added.
13. New dip switch has been added to the controller board for "Locking the operation "mode
and "Lowering the operating noise "mode.
14. A Quick Clean Kit has been added.
MXZ-A32WV -
E1
1. Indication of capacity has been changed. (BTU kW)
2. Communication system has been changed.
3. Power supply way has been changed(change to supply to outdoor unit).
4. Evaporation temperature thermistor has been removed.
5. Ambient temperature thermistor has been added.
6. New dip switch has been added to the controller board for "Locking the operation "mode
and "Lowering the operating noise "mode.
7. A Quick Clean Kit has been added.
has been added.