F-56
MAIN TRANSFORMER AND CHOKE REMOVAL
AND REPLACEMENT PROCEDURE (continued)
MAIN TRANSFORMER REMOVAL
10. With the 1/2" wrench, remove the six trans-
former secondary leads from the SCR heat
sink assembly.
11. Remove the transformer primary leads from
the reconnect panel. Label for reassembly.
12. Carefully label and unsolder the following
leads from the transformer windings. Cut
any necessary cable ties. See the Wiring
Diagram.
335
336
331
332
333
334
13. Using a rope sling and hoist, support the
iron/coil assembly. See Figure F.21.
14. With the 9/16" wrench, remove the four
bolts, washers and nuts holding the iron/coil
assembly to the frame assembly.
15. Cut or remove any necessary cable ties.
16. Using the hoist, carefully remove the
iron/coil
machine. Clear all leads.
TROUBLESHOOTING & REPAIR
203
31
204
32A
205
41
206
42A
207
41
thermostat
208
assembly
from
the
DC-655
IDEALARC DC-655
REASSEMBLY
1. Using the rope sling, carefully position the
iron/coil assembly onto the DC-655. Mount
it to the frame assembly with four bolts,
washers and nuts.
2. Attach the transformer primary leads to the
reconnect panel.
3. Attach the six transformer secondary leads
to the SCR heat sink assembly.
4. Solder the following leads to the transformer
windings.
335
203
336
204
331
205
332
206
333
207
334
208
5. Using a crane or hoist, carefully place the
choke onto the main transformer.
6. Attach the high inductance output lead to
the bottom choke lead.
7. Attach the low inductance output lead to the
choke center tap.
8. Attach the #222A lead and flexible trans-
former secondary lead to the top choke
lead.
9. Attach leads #273 and 41A to the choke
thermostat.
10. Replace any cable ties cut at disassembly.
11. Install the case top and sides.
F-56
31
32A
41
42A
41
thermostat