C-8
FIGURE C.4 - LN-8 OR LN-9 WIRE FEEDER CONNECTION TO THE IDEALARC DC-655
CONNECTING THE LN-8 OR LN-9 TO THE
IDEALARC DC-655 (TERMINAL STRIP)
1. Set the Idealarc DC-655 POWER toggle switch to
the OFF (0) position.
2. Disconnect main AC input power to the Idealarc
DC-655.
3. Connect the wire feeder control cable leads to the
Idealarc DC-655 terminal strip as shown in Figure
C.4.
4. Connect the wire feeder control cable ground lead
to the frame terminal marked
5. Extend wire feeder control cable lead #21 so it can
be connected directly to the work piece.
a. Make a bolted connection using AWG #14 or
larger insulated wire. Tape the bolted connec-
tion with insulating tape.
b. An S-16586- X remote voltage sensing work
lead is available for this purpose.
c. Keep the #21 lead electrically separate from
the work cable circuit and connection.
d. Tape the #21 lead to work cable for ease of
use.
ACCESSORIES
POWER SOURCE
21
TO LN-8 OR LN-9
INPUT CABLE PLUG
CONTROL
21
21
41
75 76 77
+
-
4
2
31 32
NEGATIVE
POSITIVE
ELECTRODE CABLE
TO WIRE FEED UNIT
}
TO WORK
REMOTE VOLTAGE SENSING LEAD
6. Connect LN-9 wire feeder control jumpers on
Voltage Control board.
Manual.
NOTE: The connection diagram shown in Figure C.4
a. Set the Idealarc DC-655 POWER toggle
b.
.
c. Move the work cable to the positive (+) output
d. Connect control cable lead #21 to "+21" on
7. Set the OUTPUT CONTROL switch to the
"Remote" position and the OUTPUT TERMINALS
switch to the "Remote" position.
IDEALARC DC-655
CABLE
}
C
N.E.
B
A
32
31
2
4
GND
21
See LN-9 Operator's
shows the electrode connected for positive
polarity. To change polarity:
switch to the OFF (0) position.
Move the electrode cable to the negative (-)
output terminal (High inductance or low
inductance as needed).
terminal.
the terminal strip.