PROBLEMS
(SYMPTOMS)
The input contactor chatters.
The machine is dead - the input
contactor does not operate. The
pilot light is lit.
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-800-833-9353.
TROUBLESHOOTING & REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
OUTPUT PROBLEMS
1. Check the three-phase input
line voltage at the machine.
The input voltage must match
the rating plate and reconnect
panel configuration.
1. Check the three-phase input
line voltage at the machine.
The input voltage must match
the rating plate and reconnect
panel configuration.
2. Turn the machine off and then
back on to reset the fault pro-
tection circuit. See the Control
Board LED Chart.
CAUTION
IDEALARC DC-655
TROUBLESHOOTING GUIDE
RECOMMENDED
COURSE OF ACTION
1. Check for loose or faulty wiring
between
the
input
switch (SW1), the fault protec-
tion relay (CR2) and the input
contactor.
See the Wiring
Diagram.
2. The fault protection relay (CR2)
may have defective contacts.
Check or replace.
3. The control board may be
defective.
See the Control
Board LED Chart.
4. The input contactor may be
faulty.
1. Check the wiring between the
fault protection relay (CR2) and
the input contactor (CR1).
2. The fault protection relay (CR2)
may have defective contacts.
Check or replace.
3. The input contactor may be
faulty.
F-5