F-26
MAIN TRANSFORMER (T1) VOLTAGE TEST (continued)
LED7
LED1
LED3
LED5
15. Locate plug J5 on the firing board. See
Figure F.9.
ELECTRIC SHOCK
16. Turn on the DC-655 and check for approx-
imately 32 VAC at the following leads and
pins at plug J5. These are the phase angle
winding voltages. See Fig. F.9.
Plug J5 pin-15 (lead #203) to pin-16 (lead
#204)
Plug J5 pin-8 (lead #205) to pin-7 (lead
#206)
Plug J5 pin-6 (lead #207) to pin-5 (lead
#208)
TROUBLESHOOTING & REPAIR
FIGURE F.9 - FIRING BOARD PLUG J5 PINS
LED8
LED9
LED2
LED4
LED6
WARNING
can kill.
• Do not touch electrically hot
parts.
IDEALARC DC-655
(205) 8
(206) 7
(207) 6
(208) 5
4
3
G2699-[ ]
2
1
LED10
FIRING BOARD
17. Locate plug J13 on the optional digital
meter board. If a digital meter board is not
in place, plug J13 will not be used but will
be present in the harness. Check the fol-
lowing voltages at the appropriate leads
and pin locations.
10 VAC Plug J13 pin-1 (lead #331) to pin-2
(lead #332)
10 VAC Plug J13 pin-4 (lead #333) to pin-5
(lead #334)
42 VAC Plug J13 pin-3 (lead #335) to pin-6
(lead #336)
18. If the correct primary voltages are applied
to the main transformer and any of the sec-
ondary voltages are missing or not correct,
the transformer may be faulty.
NOTE: Always check the wiring between
the transformer windings and the test
points before replacing the transformer.
F-26