Specification Of Electrical Parts; Indoor Unit (For 13Nkv); Indoor Unit (For 16Nkv) - Toshiba RAS-13NKV-E Service Manual

Table of Contents

Advertisement

5. SPECIFICATION OF ELECTRICAL PARTS

5-1. Indoor Unit (For 13NKV)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo. sensor (TA-sensor)
3
AC-AC transformer (T01)
4
Microcomputer
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C50)
9
Fuse (F01)
10
Regulator IC (IC08)
11
Regulator IC (IC11)
12
Varistor (R21, R109)
13
Louver motor
5-2. Incoor Unit (For 16NKV)
No.
Parts name
1
Fan motor (for indoor)
2
Thermo. sensor (TA-sensor)
3
DC-DC transformer (T01)
4
Microcomputer
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01
7
Diode (DB01)
8
Capacitor (C03)
9
Fuse (F01)
10
Power supply IC (IC01)
11
Varistor (R21, R109)
12
Resistor (R01)
13
Louver motor
Type
SKF-220-20-4A-1
———
TT-10
µPD780024AGK
———
SS11V-06270
KBP06M
LXV35VB2200MJ20
BET 3.15A, 250VAC
NJM7812
NJM7805
15G561K
24BYJ48
Type
ICF-340-30-2
———
SWT-70
µPD780024AGK
———
SS11V-06270
D3SBA60
KMH450VSSN120M25C
FCU250V, 3.15A
STR-L472
15G561K
RF-5TK4R7
24BYJ48
– 19 –
FILE NO. SVM-05027
Specifications
AC Motor with 150°C thermo fuse
10 kΩ at 25°C
187 - 276V, 6VA
10 kΩ at 25°C
27 µH, AC 0.64A
1.5A, 420V
2200µF, 35 V
T3.15A, 250 V
12VDC, 1.5A max
5VDC, 1.5A max
560V
DC 12V
Specifications
DC 340 V, 30 W
10 kΩ at 25°C
DC 390 V, Secondary DC 15 V, 12 V, 7 V
10 kΩ at 25°C
27mH, AC 0.6A
4A, 600 V
120µF, 450 V
T3.15A, 250 V
560 V
4.7Ω, 5 W
DC 12V

Hide quick links: