Toshiba RAS-13NKV-E Service Manual page 82

Table of Contents

Advertisement

No.
Part name
6
Cross flow fan
7
Base bearing
Procedures
1) Remove the front panel, electrical part,
horizontal louver and the heat exchanger with
the procedure 4.
2) Remove 2 screws of the band motor (L) and
other 2 screws of the band motor (R) and then
remove the cross flow fan.
3) Loosen the set screw of the cross flow fan then
disconnect the fan and the fan motor.
Notice
For position of the fan motor connector and
drawing out of the lead cables, refer to the
procedure 5.
Fix the cross flow fan with the set screw at the
position where the gap between the back body and
the right surface of the cross flow fan is 4.5 mm.
1) Remove the front panel, electrical part,
horizontal louver, heat exchanger and the cross
flow fan with the procedure 5 and 6 .
2) Remove the 2 screws fixing the base bearing.
3) Remove the bearing from the base bearing.
If the housing protrudes from the base bearing,
put the housing in position and attach the
bearing to the base bearing.
– 81 –
FILE NO. SVM-05027
Remarks
2 2-Screws (R)
2 2-Screws (L)
4.5 mm
3 Set screws
2 2-Screws