(9) QUIET operation control.
When the [QUIET] button is pushed, the fan is
restricted the revolution speed at L- level until
the [QUIET] button is pushed once again
(cancel QUIET operation).
Remarks :
QUIET operation is appropriate to work with
less heating load condition. Because of the fan
speed L- may cause not enough the heating
capacity.
8-2-4. Automatic operation
(1)
As shown in Fig. 8-2-12, the operation mode
(COOL, DRY, HEAT) is selected according to the
Preset temperature and room temperature when
the operation has started.
If room temperature is higher than 1°C of perset
temperature. "Cooling" operation is performed.
If room temperture is within 1°C of perset
temperature. "Fan only" operation is performed.
(at UL speed).
If room temperture is lower than 1°C of perset
temperture. "Heating operation is performed.
Ta
Cool Operation
Ts+1
Ts
Fan Only
Ts-1
Heat Operation
Fig. 8-2-12

8-3. Temporary Operation

Temporary Auto operation, existence of Auto
Restart, and Temporary Cooling operation can be
set by the [RESET] button of the indoor
controller.
TEMPORARY button
OFF → ON
After pushing button
for 3 seconds
After pushing button
for 10 seconds
8-3-1. Temporary auto operation
When the [RESET] button is pushed, the
Auto operation with set temperature fixed at 25°C
starts. Controlling is same as that of Auto opera-
tion by the remote controller.
When the [RESET] button is pushed again,
the operation stops.
During Temporary Auto operation, operation by the
remote controller is accepted.
Using the Auto Restart function, the Temporary
Auto operation starts when power failure is reset.
8-3-2. Temporary cooling operation
When the [RESET] operation button keeps
pushed for 10 seconds, Cooling operation of
which compressor motor speed and the indoor fan
speed are fixed starts.
Compressor motor speed :
When the [RESET] operation button is
pushed again, the operation stops.
Auto Restart function is unavailable.
− 37 −
FILE NO. SVM-05027
RESET
Fig. 8-3-1
Table 8-3-1
Control
Temporary Auto operation start
Auto Restart
control select
Temporary Cooling
operation start
30 rps
Indoor fan speed : Low