5-4. Outdoor Unit (For 16NAV)

No.
Parts name
1
SC coil
(Noise filter)
2
DC-DC transformer
3
Reactor
4
Outside fan motor
5
Suction temp. sensor
(TS sensor)
Discharge temp. sensor
6
(TD sensor)
Outside air temp. sensor
7
(TO sensor)
Heat exchanger temp.
8
sensor (TE sensor)
9
Terminal block (6P)
10
Fuse
11
Electrolytic capacitor
12
IGBT
13
Compressor
14
Rectifier
Model name
L01
ADR2516-0R6TB
L03
ADR2520-R15TB
SWT-72
CH-57-Z-T
ICF-140-43-4
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
JXO-6B
For protection of switching power source
For protection of inverter input overcurrent
LLQ2G761KHUBTF
GT20J321
DA89X1F-23F
D25XB60-400 1
– 21 –
FILE NO. SVM-05027
Rating
15A, 0.6m H
20A, 0.15mH
Primary side DC280V, Secondary
side 7.0 V x 1, 12 V x 1, 17V x 2
L=10mH, 16A x 2
DC140 V, 43 W
10 kΩ (25°C)
62 kΩ (20°C)
10 kΩ (25°C)
10 kΩ (25°C)
30A, 600 VAC
3.15A, AC 250 V
25A, AC 250 V
760µF, DC 400 V x 3 pieces
20A, 600 V
3-phases 4-poles 1100 W
20A, 600 V,