7.14
Pump (fi g. 40)
Replacement of pump head
• Isolate electricity and fl ow and return pipes
• Remove casing (two screws bottom rear corners).
• Remove the two securing screws and lower control
panel
• Release pressure from boiler via pressure relief valve
• Unplug the pump lead "A" from the pump head
• Place a piece of cloth or other absorbent material
over the rear of the control panel to catch any
drops of water that may fall when the pump head
is removed.
• Using a 4mm allen wrench undo the four allen screws
"B" in the pump head, lift away pump head from
the pump body
• fi t new head into pump body and secure with the
allen screws tightening evenly.
• Replace electrical connection.
Replacement of pump od (fi g. 40)
• Proceed as for removal of pump head
• Disconnect the expansion vessel connecting pipe "E"
from the rear of the pump body by removing the clip
from the left hand side
• Disconnect the boiler return pipe
• Disconnect the pump to heat exchanger connection
by removing the clip "F"
• Unscrew the nut on bottom of pump "D"
• Turn the pump body through 90°, pull the bottom
forward and withdraw the pump body
• Reassemble in reverse order taking care to ensure the
O-rings are in place and undamaged.
7.1 Remo al of heat e chan e
• Isolate gas, water and electricity supplies
• Remove casing ( screws bottom corners)
• Remove the two securing screws and lower control panel
• Drain heat exchanger for both
• Remove sealed compartment front panel
• Disconnect the overheat thermostat and central heating limit thermostat
• Remove the main burner, fan, fl ue hood and fl ow meter as described previously
• Remove the pump to heat exchanger fl ow connection and locknut
• Undo the domestic water outlet connection and locknut
ift out heat exchanger
• Re-assemble in reverse order
A
D
Fig. 40
35