Technical Data - Baxi 100 He Installation And Servicing Instructions

Wall mounted powered flue condensing boiler gas fired central heating unit
Hide thumbs Also See for 100 He:
Table of Contents

Advertisement

Appliance Type
C
Appliance Category
CAT I
Heat Input
Max
(see note)
kW
33.76
Btu/h
115,200
Heat Output
(Non Condensing 70° C Mean Water Temp)
Max
kW
30.18
Btu/h
102,980
Heat Output
(Condensing 40° C Mean Water Temp)
Max
kW
32.61
Btu/h
111,280
Max Gas Rate (Natural Gas)
(After 10 Mins)
Btu/hr
102,980
m
3
/h
2.95
ft
3
/h
104.2
Inlet Pressure at Gas Valve (Natural Gas)
Min
18.1 mbar
Max
22.5 mbar
(see Section 10.1)
Injector (Natural Gas)
6.3mm Diameter
NOTE: The maximum output of the
boiler is factory set at 22.0kW
(75,000 Btu/hr). This can be altered
to 30.18kW (102,980 Btu/hr)
- see section 8.8.
SEDBUK Declaration For 100 HE
The efficiency is 90.9%
This value is used in the UK Government's
Standard Assessment Procedure (SAP) for
energy rating of dwellings. The test data from
which it has been calculated has been
certified by 0086.
C
Nox Class
13
33
Horizontal
2H
Flue Terminal
Min
Dimensions
10.2
Connections
34,840
Gas Supply
Central Heating Flow
Central Heating Return
Condensate Drain
Min
Outercase Dimensions
9.14
Overall Height
31,180
Casing Height
Casing Width
Casing Depth
Min
Clearances
10.1
(For unventilated compartments see Section 7.5)
34,520
Both Sides
Above Casing
Below Casing
Front (For Servicing)
75,000
Front (In Operation)
2.31
Weights
81.6
Packaged Boiler Carton
Packaged Flue Kit
Weight Empty
Installation Lift Weight
Recommended System
Temperature Drop
Normal
Condensing 20°C
220
200
180
160
140
120
100
5
Diameter
110mm
Projection
150mm
-
/
in BSPT
1
2
-
28mm
-
28mm
-
1 in BSP
-
750mm
Inc Flue Elbow
-
600mm
-
390mm
-
320mm
5mm Min
200mm Min
50mm Min
500mm Min
5mm Min
kg
lb
40.7
89.6
3.6
8.0
38.2
84.1
31.5
69.3
11°C
20°F
36°F
Hydraulic Resistance Chart
80
60
40
20
0
10
Water Flow Rate (litres/min)

4.0 Technical Data

Electrical Supply
(Appliance must be connected to an
earthed supply)
Power Consumption
External Fuse Rating
Internal Fuse Rating (BS 4265)
Fuse (2)
4 AT (Control Board)
Fuse (3)
2 AT (Ignition Board)
Water Content
litres
2.6
pints
4.6
Static Head
max
30 metres (100 ft)
min
1 metre (3.25 ft)
Low Head
0.2m (8 in) min
System Detail
fully pumped open vented & sealed systems
Gas Connection
RC
Controls
boiler thermostat, safety thermostat,
flow switch, electronic flame sensing,
temperature protection thermostat &
condensate blockage sensor
20
30
230V~ 50Hz
80W
3A
1
/
(
1
/
in BSPT)
2
2
9.1
8.3
7.5
6.6
5.8
5.0
4.2
3.3
2.5
1.7
0.8
40
7