Technical Data - Baxi Bermuda Inset 2 Boiler 50/4 Installation And Servicing Manual

Fireside gas central heating unit
Table of Contents

Advertisement

2.0
Technical Data - Page 5
Inset 2 50/4 hydraulic resistance
SEDBUK Declaration For Inset 2 50/4
The seasonal efficiency (SEDBUK) is 72 %
This value is used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of
dwellings.
The test data from which it has been calculated have
been certified by 0086.
Bermuda Inset 2 Boiler 50/4
The Boiler is for use with Natural Gas only.
Heat Input
Max
kW
18.79
Btu/h
64,100
Heat Output
Max
kW
14.65
Btu/h
50,000
Burner Pressure
Max
mbar
17
in wg
6.8
Water Content
Max
litres
1 6
gallons
0.35
Thermocouple
9.5 - 11 5mv
Output
Gas Connection
R
½ (½ in BSPT)
c
Water Connections
3 x 1 in BSP
Electricity Supply
230V ~ 50Hz
External fuse - 3 Amp
Appliance Rating - 4.8 watt
Controls
Multi-functional gas valve, mechanical thermostat,
thermocouple with permanent pilot & atmospheric
sensing device
Gas Rate
1.8m
(after 10 mins)
(63.57ft
Lifting Weight
32.1 kg (70.7 Ibs)
Dimensions
Height
Width
Depth
Flue Diameter
mm
125
in
5
Heat Exchanger
Cast Iron
Low Head
(Min)
mm
1000
3
in
39
/
8
Water Content
Fully pumped or pumped heating with gravity hot
water. Sealed system with optional overheat
thermostat
5
Mid
17
58,070
Mid
13.19
45,000
Mid
14
5.6
3
/h
3
/h)
516mm
440mm
368mm
Min
15.2
51,850
Min
11.72
40,000
Min
11
4.4

Hide quick links: