13.0 Changing Components – page 40
Fig. 75
13.25
Hydraulic Control Board
1.
Remove the facia cover by removing the securing
screws and pulling it forwards whilst lifting (Fig. 73).
2.
Remove all the connections from the control board
(Plugs are removed by springing the retaining clip
outwards and withdrawing them vertically).
3.
Remove the screws fixing the control board to the facia
panel and withdraw the board taking care to leave the
temperature control spindles in place (Fig. 75).
4.
Fit the new control board and reassemble in reverse
order.