Installation – page 23
Fig. 34
Fig. 35
Fig. 36
8.9
Fitting a Room Thermostat
1.
A 2-wire or 3-wire room thermostat can be fitted to the
Baxi Bahama 100 terminal block.
2.
To fit a 2-wire thermostat, remove link and wire the
thermostat switch between positions 3 & 4 (Fig. 34).
3.
To fit a 3-wire thermostat, remove link and wire the
thermostat switch between positions 3 & 4. The
anticipator should be wired to position 5, as this
provides a continuous mains neutral (Fig. 35).
4.
A cable clamp is provided for incoming cables.
8.10
Fitting a Programmable Room Thermostat
1.
If a Baxi Combi Controller is fitted refer to the
instructions supplied with it.
8.11
Fitting a Frost Thermostat (Fig. 36)
1.
The frost thermostat is connected between positions 1
and 4.
2.
If room and frost thermostats and a timer are to be
incorporated in the control system they should be wired
as shown (Fig. 36).
3.
Secure the incoming cable/s with the cable clamp and
replace the cover