Three Conductor Wire Connection To Range - Electrolux 30" Service Manual

Electric freestanding ranges
Hide thumbs Also See for 30":
Table of Contents

Advertisement

• This appliance must be connected to a
grounded, metallic, permanent wiring system,
or
a
grounding
connected to the grounding terminal or wire
lead on the appliance.
• Do not use the gas supply line for grounding
the appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.

Three Conductor Wire Connection to Range

If local codes permit connection of the frame
grounding conductor to the neutral wire of the
copper power supply cord (see Figure 3):
1. Remove the 3 screws at the lower end of the
rear wire cover, then bend the lower end of the
rear wire cover (access cover) upward to expose
range terminal connection block (see Figure 2).
To gain access to lower
terminal block bend lower
back cover plate along row
Figure 2
2. Remove the 3 loose nuts (after you removed the
rubber band) on the terminal block using 3/8" nut
driver or socket.
3. Connect the neutral white wire of the copper
power supply cord to the center silver-colored
terminal of the terminal block, and connect the
other wires to the outer terminals. Match wires
and terminals by color (red wires connected to
the right terminal, black wires connected to the
left terminal).
4. Replace the 3 nuts on the terminal block (see
figure 3).
connector
should
of holes shown here
5. Lower the terminal cover and replace the 3
screws.
be
Terminal
Block
Black
Wire
A user
supplied strain-
relief must be
installed at this
location
Four Conductor Wire Connection to Range
(mobile homes)
1. Remove the 3 screws at the lower end of the rear
wire cover, then raise the lower end of the rear
wire cover (access cover) upward to expose range
terminal connection block (see figure 2).
2. Remove the three loose nuts (after you removed
the rubber band) on the terminal block using a 3/8"
nut driver or socket.
3. Remove the grounding strap from the terminal
block and from the appliance frame.
4. Connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame
where ground strap was removed (see figure 4).
5. Connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by
color (red wires connected to the right terminal,
black wires connected to the left terminal).
6. Replace the 3 nuts on terminal block (see figure 4).
7. Lower the terminal cover and replace the 3
screws.
25
Silver Colored
Terminal
Red
Wire
Neutral
(White Wire)
Grounding
Strap
1-1/8" Dia.
Direct
Connection
To 240 V receptacle
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
Figure 3