30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
Three Conductor Wire Connection to
Range
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power
supply cord (see Figure 7):
1. Remove the screws from the access plate at the
lower right end of the rear cover to expose range
terminal connection block.
2. Using the nuts supplied in the literature package,
connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal) (see fi gure 7).
3. Replace the terminal cover and replace the screws.
Terminal
Block
Black
Wire
A User Supplied
Strain-relief Must
Be Installed at This
Location.
Figure 7
Silver Colored Terminal
Red Wire
Cord
Mounting
Plate
Neutral
(White Wire)
Grounding
Strap
1 1/8" (2.9 cm) Dia.
Direct Connection
Hole. Punch Out
To 240 V
Knockout for 1 3/8"
Receptacle
(3.5 cm) Dia. Cord
Kit Hole.
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of the
frame grounding conductor to the neutral wire of the
copper power supply cord (see Figure 8):
1. Remove the screws from the access plate at the
lower right end of the rear cover to expose range
terminal connection block.
2. Remove the grounding strap from the terminal
block and from the appliance frame.
3. Using the nuts supplied with the literature package,
connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame
where the ground strap was removed (see Figure
8).
4. Connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal).
5. Replace the terminal cover and replace the screws.
Terminal Block
Black Wire
1 1/8" (2.9cm)
Dia. Direct
Connection
Hole. Punch
Out Knockout for
1 3/8" (3.5cm)
Dia. Cord Kit
Hole.
A User Supplied
Strain-relief Must
Be Installed at
This Location
NOTE: Be sure to remove the
supplied grounding strap.
5
Silver Colored Terminal
Neutral
(White Wire)
Ground (Bare
Copper Wire)
To 240 V Receptacle
Figure 8
Red
Wire