52
Finalizing the Installation
3
Follow the directions below to replace the orifice.
Slide the air shutters all
a
the way to the right.
Remove and discard the front burner
b
gasket (used only for NG installations)
Front Burner
Orifice
Use a 1/2" open end wrench
c
to unscrew the two orifices.
e
Screw each LP orifice in so the
orifice protrudes 15/16" (24mm)
(indicating full insertion).
Travis Industries
(for qualified installers only)
1/2" Wrench
Rear
Burner
Orifice
15/16"
24mm
4141209
d
Apply thread sealant to the LP
orifices prior to installation. Use
the chart below to identify the
correct orifices.
Look here for the orifice identification
NG
LP
Front
#56
#67
Rear
#50
1.1
100-01378