10-3-7 RUBBER MOUNTS
Install the four rubber
mounts (rubber vibration isolators).
NOTE: The rubber mounts have been
so
selected that their
vibration will be most suitable to the type and frequency of
the generator. Thus, the ones of the correct rubber must be
used.
NOTE: Bowl-shaped rubber mounts must
be installed as
shown Fig.
10-23.
+
RUBBER MOUNT
Fig.
10-23
10-4 CONTROL BOX DISASSEMBLY and
REASSEMBLY
10-4-1 DISASSEMBLY
-~
~~
~
~
1)
Disconnect all the connectors inside the control box.
~~~
.
~
~.
.~~
3)
Remove the front panel. (See Fig.
10-24.)
Remove the front panel parts individually after discon-
necting their leads.
NOTE: The fuse holder has its leds soldered so that
they must be unsoldered before removing
the fuse
holder. The dual voltage
type
uses
two fuse holders.
The other types also have
two fuse holders, but use
only one of them. The other is a spare.
Remove the AVR.
4) Disconnect the
DC
terminal
and
DC
fuse holder, and
Fig.
10-24
remove them.
NOTE: The fuse holder has its leads soldered.
10-4-2 REASSEMBLY
Reverse the disassembly procedure.
NOTE: The wires are colored for easy identification, and of the correct size to suit the capacity. The connectors used also
meet the requirements. If the wires are disconnected, be sure to reconnect the same wires or wires of the Same kind.
-
51
-