AC OUTPUT MEASURING
TO A
Fig. 8-
7
;e a circuit like the one shown in Fig. 8-7 for measuring AC output. A hot plate or lamp with a power factc )r of 1
. O
may
be used as a load. Adjust the load and rpm, and check that the voltage range is as specified in Table 8-1 at the rated amperage
and rated rpm.
Ratedvoltage
I
11OV
1
12OV
1
22OV
230V
2 3 8 - 2 4 5 V
Voltagerange
'
1 0 8 - 1 1 5 V
j
1 1 8 - 1 2 5 V
I
2 1 8 - 2 2 5 V
1
2 2 8 - 2 3 5 V
I
240 V
I
8 - 3
DC OUTPUT MEASURING
Table
8-
1
0 0
SWITCH
@
DC TERMINAL
Fig.
8-8
Switch the power on: adjust the load to 8.3 A at the rated rpm, and check that the voltage is within the range of 13 to 11
V.
NOTE: If a battery is connected as the load, the ouwut voltage increases by about 1 to 2 V, possibly causing battery over-
charge. Control battery liquid level during charging to prevent overcharging.
8 - 4
MEASURING INSULATION RESISTANCE
Connect a megger tester to one of the two receptacle output
terminals and the ground terminal, then measure the insula-
tion resistance. (Ifyourgenerator is the no-fise breaker type,
close the no-fuse breakerand measure it. If yourgenerator is
the dual voltage type, any voltage receptacle may be used.)
An
insulation resistance of 1 megohms or more is normal.
(The original insulation resistance at the time of shipment
from the factory is 10 megohms or more.) If it is less than
1 megohm, disassemble the generator and
measure the
insulation resistance of tne stator, rotor
and control box
individually.